Model | AA2914 | AA2918 | AA2928 | |||
Optical System | Optical Type | Single beam | Single beam | Double beam | ||
Monochromator | Czerny-Turner type with focal lengths at 350mm | |||||
Wavelength Range | 190-900nm | |||||
Grating | Holographic diffraction grating with 1800 lines/mm | |||||
Slits | Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm | |||||
Wavelength Accuracy | ±0.3 nm | ±0.2 nm | ±0.15 nm | |||
Wavelength Repeatability | ±0.1nm | ±0.1nm | ±0.05nm | |||
Lamp Holder | Automated 4-lamp turret | Automated 8-lamp turret | ||||
Detector | Wide range UV sensitive photomultiplier tube | |||||
Photometric Performance | Reading Mode | Transmittance(T), Absorbance(A), Concentration(C) | ||||
Photometric Range | 0-125%, -0.1-3.00A | |||||
Static Baseline Drift (Cu) | ≤0.004A/30 min | ≤0.003A/30 min | ≤0.002A/30 min | |||
Dynamic Baseline Drift (Cu) | ≤0.006A/15 min | ≤0.005A/15 min | ≤0.004A/15 min | |||
Background Correction | Deuterium (D2) Background Correction | D2 and Self-absorption | ||||
Flame Analysis | Characteristic Concentration | Cu≤0.04ug/ml | Cu≤0.035ug/ml | Cu≤0.035ug/ml | ||
Detection Limit | Cu≤0.008ug/ml | Cu≤0.006ug/ml | Cu≤0.004ug/ml | |||
Repeatability (Cu) | RSD≤1% | RSD≤0.6% | RSD≤0.5% | |||
Acetylene Flow Control | Auto 12-level | Auto 12-level | Auto 12-level | |||
Air Flow Control | Auto 4-level | Auto 4-level | Auto 4-level | |||
Nebulizer | High efficiency glass | |||||
Burner Adjustment | Automatic up and down | |||||
Burner Head | Titanium alloy 100mm burner for air/acetylene operation | |||||
Premix Chamber | Corrosion resistant | |||||
Safety Protection | Flame sensor, gas leak sensor, gas pressure sensor | |||||
Data Processing | Software | RGWIN AAS software pacakage | ||||
Analytical Method | Flame AA, Flame AE, Hydride Generation | |||||
Concentration Calculation Method | Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation | |||||
Repeated Measurement Times | 1-30 times, calculate the average, show SD and RSD value of absorbance and concentration | |||||
QA/QC Function | Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration | |||||
Report Printing | Parameter printing, resulting printing | |||||
Communication Port | Standard RS-232 | |||||
Others | Computer | External(excluded) | ||||
Dimension & Weight | 850*650*550MM(W*D*H), 100Kg | |||||
Power Supply | 110/220V, 50/60Hz | |||||
Working Environment | Temperature 10 ~ 35 °C, Humidity≦85% |
NO. | Description | Qty | NO. | Description | Qty |
1 | Main Unit | 1 | 8 | 6mm air tube(transparent) | 10m |
2 | Power Cable | 1 | 9 | USB(manual and software) | 1 |
3 | Data Cable | 1 | 10 | Drain Tube | 2m |
4 | Screw Driver | 1 | 11 | Acetylene pressure reducing valve connector | 1 |
5 | Cu HCL | 1 | 12 | 5A fuse | 3 |
6 | Air Compressor | 1 | 13 | Ignition filament | 5 |
7 | 6mm acetylene tube(orange) | 10m |
Quality | 1. Our products have good quality and very positive reputations in the market. 2. Customers are very happy with them and have a lot of good comments about our intruments and service. | |
Delivery Time | 1. We can get them ready 3-5 days after order confirmation for small orders. 2. For big quantities, need to be confirmed. 3. In most cases, fast delivery is guaranteed. | |
Technical Support | 1. We have service manual. If not, detailed documents or videos will be provided. 2. We can provide online or site training in our factory. 3. We can have video conference at any time. | |
Aftersales Support | 1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference. 2. Within warranty, we will solve the problem for you with no charge(except for consumables). 3. You can call, text or email us at any time. We have good English speakers. | |
Warranty Time | One year and extendable | |
Our product advantages are as follws: |
Q: What areas and applications can it be used? | ||||||||
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc. | ||||||||
Q: Does it need any installation | ||||||||
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it. | ||||||||
Q: What standard accessories are included? | ||||||||
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1 cm quartz cuvette(UV models), one USB with user manual and power cable. | ||||||||
Q: Is PC software included? | ||||||||
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested. | ||||||||
Q: Why the reading is red and reach its maximum value 3.00Abs? | ||||||||
A: Probably you use the glass cuvette in UV range. | ||||||||
Q: Why the wavelength calibration or self checking fail? | ||||||||
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself. | ||||||||
Q: Why is the reading is not as accurate as before? | ||||||||
A: Do the wavelength calibration before testing or restore the device to its default factory settings. | ||||||||
Q: Why PC software can not be installed successfully? | ||||||||
A: Close your anti-virus software on the computer and do it again. | ||||||||
Q: Why the software can not be connected successfully? | ||||||||
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is. | ||||||||
Q: Can the data transferred to USB or PC? | ||||||||
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software. | ||||||||
Q: Why the Abs value is negative(lower than zero). | ||||||||
A: Do the blanking or change the reference sample. |